toggle_dcline
- toggle_dcline(mpc, on_off)
toggle_dcline()
- Enable, disable or check status of DC line modeling.MPC = TOGGLE_DCLINE(MPC, 'on') MPC = TOGGLE_DCLINE(MPC, 'off') T_F = TOGGLE_DCLINE(MPC, 'status') Enables, disables or checks the status of a set of OPF userfcn callbacks to implement DC lines as a pair of linked generators. While it uses the OPF extension mechanism, this implementation works for simple power flow as well as OPF problems. These callbacks expect to find a 'dcline' field in the input MPC, where MPC.dcline is an ndc x 17 matrix with columns as defined in IDX_DCLINE, where ndc is the number of DC lines. The 'int2ext' callback also packages up flow results and stores them in appropriate columns of MPC.dcline. NOTE: Because of the way this extension modifies the number of rows in the gen and gencost matrices, caution must be taken when using it with other extensions that deal with generators. Examples: mpc = loadcase('t_case9_dcline'); mpc = toggle_dcline(mpc, 'on'); results1 = runpf(mpc); results2 = runopf(mpc);
See also
idx_dcline()
,add_userfcn()
,remove_userfcn()
,run_userfcn()
.