IDX_DCLINE Defines constants for named column indices to dcline matrix. Example: c = idx_dcline; Some examples of usage, after defining the constants using the line above, are: mpc.dcline(4, c.BR_STATUS) = 0; % take branch 4 out of service The index, name and meaning of each column of the branch matrix is given below: columns 1-17 must be included in input matrix (in case file) 1 F_BUS f, "from" bus number 2 T_BUS t, "to" bus number 3 BR_STATUS initial branch status, 1 - in service, 0 - out of service 4 PF MW flow at "from" bus ("from" -> "to") 5 PT MW flow at "to" bus ("from" -> "to") 6 QF MVAr injection at "from" bus ("from" -> "to") 7 QT MVAr injection at "to" bus ("from" -> "to") 8 VF voltage setpoint at "from" bus (p.u.) 9 VT voltage setpoint at "to" bus (p.u.) 10 PMIN lower limit on PF (MW flow at "from" end) 11 PMAX upper limit on PF (MW flow at "from" end) 12 QMINF lower limit on MVAr injection at "from" bus 13 QMAXF upper limit on MVAr injection at "from" bus 14 QMINT lower limit on MVAr injection at "to" bus 15 QMAXT upper limit on MVAr injection at "to" bus 16 LOSS0 constant term of linear loss function (MW) 17 LOSS1 linear term of linear loss function (MW/MW) (loss = LOSS0 + LOSS1 * PF) columns 18-23 are added to matrix after OPF solution they are typically not present in the input matrix (assume OPF objective function has units, u) 18 MU_PMIN Kuhn-Tucker multiplier on lower flow lim at "from" bus (u/MW) 19 MU_PMAX Kuhn-Tucker multiplier on upper flow lim at "from" bus (u/MW) 20 MU_QMINF Kuhn-Tucker multiplier on lower VAr lim at "from" bus (u/MVAr) 21 MU_QMAXF Kuhn-Tucker multiplier on upper VAr lim at "from" bus (u/MVAr) 22 MU_QMINT Kuhn-Tucker multiplier on lower VAr lim at "to" bus (u/MVAr) 23 MU_QMAXT Kuhn-Tucker multiplier on upper VAr lim at "to" bus (u/MVAr) See also TOGGLE_DCLINE.
0001 function c = idx_dcline 0002 %IDX_DCLINE Defines constants for named column indices to dcline matrix. 0003 % Example: 0004 % 0005 % c = idx_dcline; 0006 % 0007 % Some examples of usage, after defining the constants using the line above, 0008 % are: 0009 % 0010 % mpc.dcline(4, c.BR_STATUS) = 0; % take branch 4 out of service 0011 % 0012 % The index, name and meaning of each column of the branch matrix is given 0013 % below: 0014 % 0015 % columns 1-17 must be included in input matrix (in case file) 0016 % 1 F_BUS f, "from" bus number 0017 % 2 T_BUS t, "to" bus number 0018 % 3 BR_STATUS initial branch status, 1 - in service, 0 - out of service 0019 % 4 PF MW flow at "from" bus ("from" -> "to") 0020 % 5 PT MW flow at "to" bus ("from" -> "to") 0021 % 6 QF MVAr injection at "from" bus ("from" -> "to") 0022 % 7 QT MVAr injection at "to" bus ("from" -> "to") 0023 % 8 VF voltage setpoint at "from" bus (p.u.) 0024 % 9 VT voltage setpoint at "to" bus (p.u.) 0025 % 10 PMIN lower limit on PF (MW flow at "from" end) 0026 % 11 PMAX upper limit on PF (MW flow at "from" end) 0027 % 12 QMINF lower limit on MVAr injection at "from" bus 0028 % 13 QMAXF upper limit on MVAr injection at "from" bus 0029 % 14 QMINT lower limit on MVAr injection at "to" bus 0030 % 15 QMAXT upper limit on MVAr injection at "to" bus 0031 % 16 LOSS0 constant term of linear loss function (MW) 0032 % 17 LOSS1 linear term of linear loss function (MW/MW) 0033 % (loss = LOSS0 + LOSS1 * PF) 0034 % 0035 % columns 18-23 are added to matrix after OPF solution 0036 % they are typically not present in the input matrix 0037 % (assume OPF objective function has units, u) 0038 % 18 MU_PMIN Kuhn-Tucker multiplier on lower flow lim at "from" bus (u/MW) 0039 % 19 MU_PMAX Kuhn-Tucker multiplier on upper flow lim at "from" bus (u/MW) 0040 % 20 MU_QMINF Kuhn-Tucker multiplier on lower VAr lim at "from" bus (u/MVAr) 0041 % 21 MU_QMAXF Kuhn-Tucker multiplier on upper VAr lim at "from" bus (u/MVAr) 0042 % 22 MU_QMINT Kuhn-Tucker multiplier on lower VAr lim at "to" bus (u/MVAr) 0043 % 23 MU_QMAXT Kuhn-Tucker multiplier on upper VAr lim at "to" bus (u/MVAr) 0044 % 0045 % See also TOGGLE_DCLINE. 0046 0047 % MATPOWER 0048 % $Id: idx_dcline.m,v 1.1 2011/12/08 20:34:20 cvs Exp $ 0049 % by Ray Zimmerman, PSERC Cornell 0050 % Copyright (c) 2011 by Power System Engineering Research Center (PSERC) 0051 % 0052 % This file is part of MATPOWER. 0053 % See http://www.pserc.cornell.edu/matpower/ for more info. 0054 % 0055 % MATPOWER is free software: you can redistribute it and/or modify 0056 % it under the terms of the GNU General Public License as published 0057 % by the Free Software Foundation, either version 3 of the License, 0058 % or (at your option) any later version. 0059 % 0060 % MATPOWER is distributed in the hope that it will be useful, 0061 % but WITHOUT ANY WARRANTY; without even the implied warranty of 0062 % MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the 0063 % GNU General Public License for more details. 0064 % 0065 % You should have received a copy of the GNU General Public License 0066 % along with MATPOWER. If not, see <http://www.gnu.org/licenses/>. 0067 % 0068 % Additional permission under GNU GPL version 3 section 7 0069 % 0070 % If you modify MATPOWER, or any covered work, to interface with 0071 % other modules (such as MATLAB code and MEX-files) available in a 0072 % MATLAB(R) or comparable environment containing parts covered 0073 % under other licensing terms, the licensors of MATPOWER grant 0074 % you additional permission to convey the resulting work. 0075 0076 %% define the indices 0077 c = struct( ... 0078 'F_BUS', 1, ... %% f, "from" bus number 0079 'T_BUS', 2, ... %% t, "to" bus number 0080 'BR_STATUS', 3, ... %% initial branch status, 1 - in service, 0 - out of service 0081 'PF', 4, ... %% MW flow at "from" bus ("from" -> "to") 0082 'PT', 5, ... %% MW flow at "to" bus ("from" -> "to") 0083 'QF', 6, ... %% MVAr injection at "from" bus ("from" -> "to") 0084 'QT', 7, ... %% MVAr injection at "to" bus ("from" -> "to") 0085 'VF', 8, ... %% voltage setpoint at "from" bus (p.u.) 0086 'VT', 9, ... %% voltage setpoint at "to" bus (p.u.) 0087 'PMIN', 10, ... %% lower limit on PF (MW flow at "from" end) 0088 'PMAX', 11, ... %% upper limit on PF (MW flow at "from" end) 0089 'QMINF', 12, ... %% lower limit on MVAr injection at "from" bus 0090 'QMAXF', 13, ... %% upper limit on MVAr injection at "from" bus 0091 'QMINT', 14, ... %% lower limit on MVAr injection at "to" bus 0092 'QMAXT', 15, ... %% upper limit on MVAr injection at "to" bus 0093 'LOSS0', 16, ... %% constant term of linear loss function (MW) 0094 'LOSS1', 17, ... %% linear term of linear loss function (MW) 0095 'MU_PMIN', 18, ... %% Kuhn-Tucker multiplier on lower flow lim at "from" bus (u/MW) 0096 'MU_PMAX', 19, ... %% Kuhn-Tucker multiplier on upper flow lim at "from" bus (u/MW) 0097 'MU_QMINF', 20, ... %% Kuhn-Tucker multiplier on lower VAr lim at "from" bus (u/MVAr) 0098 'MU_QMAXF', 21, ... %% Kuhn-Tucker multiplier on upper VAr lim at "from" bus (u/MVAr) 0099 'MU_QMINT', 22, ... %% Kuhn-Tucker multiplier on lower VAr lim at "to" bus (u/MVAr) 0100 'MU_QMAXT', 23 ); %% Kuhn-Tucker multiplier on upper VAr lim at "to" bus (u/MVAr)